The LCR Meter measures the characteristics of a passive component: capacitance, inductance, resistance, quality factor, dissipation factor, and phase angle of a component's impedance. The resistance, capacitance or inductance, and one selectable third result are displayed simultaneously on a large, low-cost LCD. The LCR Meter can display the resistive and reactive parts of either a series or parallel equivalent circuit, as well. With a rotary encoder and small keyboard, the LCR Meter provides an easy user interface.

This project features a resistance range from 100.0 mW (0.1-mW resolution) to 1.000 MW. The capacitance ranges from 100.0 pF (0.1-pF resolution) to 10.00 mF. And, the inductance range is from 10.00 µH (10-nH resolution) to 10.00 mH. In non-exhaustive accuracy tests, the LCR Meter recorded errors of only 0.07% at 10 nF, 0.16% at 10 kW, and 2.4% at 100 uH. Stimulus frequency ranges from 50 Hz to 10 kHz are supported in 195 user-selectable, crystal-controlled discrete steps. Stimulus AC amplitude is selectable from three different values: 250 mV, 500 mV, and 1 V. The stimulus DC bias can be set internally to 2 V or externally to up to 50 V. A four-wire measurement interface compensates for test setup contact resistance.