Start System
Overview Installation
& Operation Garage
Door Module Water
Level Module Temperature
Module Hardware
Design Garage
Door Sensor Water
Level Sensor Temperature
Sensor Software
Design Improvements Peace
of Mind Sources
and PDF
WATER
LEVEL MODULE
For
the water level sensor module, you must program
the network number and device number. The module
blinks two LEDs to indicate that you must program
the trip point. Press the S101 switch to start
the trip point calibration.
LED1
blinks rapidly to indicate the level programming
mode. The rate of blinking slows as the sensor
tube submerges deeper in water. This enables you
to test the sensor.
When
dealing with a sump pump hole, where filling the
hole with water during the calibration process
isn’t practical, you can calibrate the sensor
with a glass of water. Use a marker or a piece
of tape to mark the desired depth on the sensor
tube and then submerge it up to that point in
the glass of water. Press S102 to set the trip
point. You can then move the sensor and tube into
the sump hole. Mount the tube so the marked point
is at the level where an alarm is desired.