Accurate Capacitance Meter
Cypress PSoC High Integration Challenge 2004 Contest Winner


COMPARATORS

We used two comparators (CompLow and CompHigh) in this design to define the voltage range. Their threshold voltages (VLOW and VHIGH) are programmed internally using the criteria shown in Figure 4b.      

The CompHigh’s maximum value is tied to the normal operation of the current source (see Figure 4c). We used RefLOW = 0 and RefHIGH = 2, which is well below the undesired zone because VHIGH = 0.45 V. It’s certainly possible to use a higher voltage, but the VHIGH – VLOW range will be increased, which will lead to longer measuring times. Our experience shows that using a wider range does not lead to a noticeable increase in measurement accuracy.