UART
COMMANDS
The
UART is used primarily for maintenance, testing, and
taking consecutive measurements for statistical analyses.
It uses the PSoC UART module’s high-level capabilities
to parse the input commands. A space character is used
as a delimiter. CR is a line terminator.
Commands
follow a simple syntax: a single letter followed by
an integer number. The commands are listed in Table
1 After a command string is issued, the device replies
with a response listing the values of the parameters
C (no unit), H (no unit), L (no unit), R (ohms), VDD